Accreditation
The LAF technologies Advantage
The big difference between LAF technologies and many other suppliers in industry is that we pride ourselves on quality, constant improvement and accreditation. Our Testing and Calibration Laboratories are NATA accredited in accordance to ISO 17025. The company is ISO9001 quality accredited and Eco warranty accredited (environmental management standards) .
Our NATA Scope of Accreditation includes both in field Mechanical Testing Services for Controlled environments and Calibration services for Air borne Optical particle counters and Aerosol Photometers. Additionally, the company services and calibrates a wide variety of specialist systems and instruments across a diverse number of fields.
Testing & Certification Services
The scope of accreditation and services delivered by LAF technologies has been developed and refined for well over 30 years. We provide calculated exacting services for built controlled environments, associated critical equipment and instrumentation. We service, support and Validate the equipment and complex systems that we proudly supply, without the need for outsourced third party, non factory trained service providers. Our NATA Scope for these services as follows:
NATA Accredited to Australian Standard AS1807 Clean Rooms, Pharmaceutical Isolators and Workstations
NATA accreditation link
- (TEST) Air velocity and uniformity – cabinets
- (TEST) Air velocity and uniformity – clean rooms
- (TEST) Work zone integrity
- (TEST) HEPA filter installation integrity – terminal type
- (TEST) HEPA filter installation integrity – non-terminal
- (TEST) Particle count in work zone
- (TEST) Room air pressure
- (TEST) Illuminance
- (TEST) Sound level in Cleanrooms
- (TEST) Sound level at installed workstations
- (TEST) Inward air velocity – Class I cabinets
- (TEST) Air barrier containment – safety cabinets
- (TEST) UV intensity
- (TEST) Room recovery time
- (TEST) Determination of Gas tightness – Biological safety cabinets and pharmaceutical isolators
NATA Accredited Australian Standard AS/NZS 2243.8 Fume Cupboards
- Appendix B – (TEST) Face velocity
- Appendix A – (TEST) Smoke test
NATA Accredited Australian Standard AS/NZS 2243.9 Fume Cabinets
- Appendix B – (TEST) Face velocity
- Appendix A – (TEST) Smoke test
NATA Accredited International Standard NSF/ANSI 49 Biosafety Cabinetry Field Certification
- Clause N5 – (TEST) Method Series
NATA Accredited International Standard ISO 14644.1 Clean Rooms, Pharmaceutical Isolators and Workstations
- Annex B – (TEST) Particulate cleanliness
NATA Accredited International Standard ISO 14644.3 Clean Rooms, Pharmaceutical Isolators and Workstations
- Annex B.4 – (TEST) Airflow
- Annex B.5 – (TEST) Air pressure difference
- Annex B.6 – (TEST) Installed filter system leakage
- Annexes B.8 and B.9 – (TEST) Clean room temperature and humidity
- Annex B.12 – (TEST) Cleanliness recovery performance
- Annex B.13 – (TEST) Containment leakage
NATA accredited International Standard ISO 8573-4 Clean Rooms, Pharmaceutical Isolators and Workstations
- Annex B.1 – (TEST) Measurement of solid particle concentration in compressed air lines
NATA ILAC Accredited Calibration of airborne particle counters ISO 21501-4
- NATA Calibration of airborne particle counters including the requirements of ISO 21501-4 with least uncertainties of measurement of 2.4% of particle size in the range from 0.2 to 30 μm at flow rates from 1 to 100 L/m.
NATA ILAC Accredited Calibration Aerosol Photometers (PAO/DOP HEPA Filter Testing Equipment)
- NATA Calibration of aerosol photometers with oil particulates at flow rates of 2 L/min to 180 L/min
NATA ILAC Accredited Calibration of Microbial Air Samplers
- NATA Calibration of Air Samplers with flow rate uncertainty of 3.5L/min at 100 L/min
NATA accreditation Calibration link
LAF Technologies – NATA Accredited Australian Laboratory providing Test, Verification and Calibration Services