Chat with us, powered by LiveChat
File icon representing laboratory documents and scientific records storage
NATA-accredited calibration services

Guarantee the accuracy of your instruments with NATA-accredited calibration performed by qualified professionals.

File icon representing laboratory documents and scientific records storage
NATA-accredited testing services

Benefit from NATA-accredited testing services that provide independent verification of your equipment’s performance.

Icon representing laboratory features and navigation elements
Bio-Decontamination

Maintain a safe and sterile laboratory environment with expert bio-decontamination services.

Settings icon representing configuration options for laboratory or system controls
Environmental Monitoring Systems

Clean Room and Laboratory environmental monitoring system projects and technical support

Icon representing navigation or features in laboratory or scientific interface
IOQ (Installation Operational Qualification) services

Verify the proper installation and functionality of your equipment with IOQ services.

ser-6.Note icon representing laboratory documentation and scientific records
Commissioning & validation services

Ensure your equipment is properly installed, qualified, and meets performance specifications through commissioning and validation services.

Book a service technician online now

Looking to book a LAF tech service technician for repairs, calibration testing and/or maintenance? Complete our online booking form.

bugbox anaerobic workstations - Laftech
Bugbox

Bugbox Anaerobic Workstation. Baker’s anaerobic workstations are engineered specifically to help microbiologists cope with rising workloads and provide the best primary isolation rates.

uv stick UV-C lamps for disinfecting laftech
UV-STICK Portable Germicidal

UV STICK E2/75H-ST-NX-NT is a commercial grade dual lamp germicidal device with control timer panel and four wheels for easy mobility.

purair advanced ductless fume cabinet
Purair Advanced Ductless Fume Hoods

Our Purair advanced series of ductless fume hoods are a series of high efficiency products designed to protect the user and the environment from hazardous vapors generated on the work surface.

Automated Microbial Monitoring
Lighthouse Automated Microbial Monitoring Systems

LIGHTHOUSE designed the Remote Active Count system to meet the industry need for continuous trouble-free operation and flexible running parameters.

safemate cyto cytotoxic cabinets
Safemate CYTO Cytotoxic Cabinets

BioAir Safemate CYTO Cytotoxic Drug Handling Cabinets LAF Technologies is the exclusive Australian agent for BioAir and their world renowned range of professional cytotoxic cabinets.

Aerosol Photometer - Model PH-4
TEC PH-4 Precision Aerosol Photometer

PH-4 digital photometer is world’s most compact and advanced digital Aerosol Photometer utilised for testing HEPA filters.

Safekeeper evidence drying cabinet
Safekeeper Evidence Drying Cabinets

Safekeeper Forensic Evidence Drying Cabinets Evidence Drying Cabinets for Industry Professionals LAF Technologies is one of Australasia’s leading suppliers of latest generation forensic evidence drying cabinets and other specialist forensic equipment.

Memmert Incubator I Series

Available in both the regular Incubator series with SingleDISPLAY controls and the advanced Incubator Plus range with TwinDISPLAY, they are designed to meet the needs of laboratories seeking accuracy, reproducibility, and compliance with international standards.

Laboratory ovens for scientific testing and precise temperature control by Laftech
Memmert Universal Oven UN

From simple drying processes to complex conditioning procedures, the Memmert UN Series provides stable, repeatable results without the complexity of forced air systems.

Liebherr Laboratory Refrigerators Perfection Range

Modern components and precise controls ensure that the substances and materials are stored optimally.

Memmert WTB Series Water Baths

Whether you are incubating samples, thawing media, or performing routine laboratory procedures, the WTB Series ensures reliable and reproducible results.

OmniaPure XS Basic laboratory equipment used for calibration testing and cleanroom monitoring
OmniaPure xs basic

When you need ultrapure water without the fuss, the OmniaPure xs basic is your ideal solution. This compact, cost-effective system delivers Type I water with exceptional purity, boasting a resistivity of 18.2 MΩ x cm and a low TOC value of < 10 ppb.

Venus 1 laboratory equipment used for calibration testing and cleanroom monitoring
BIOSAFE VENUS® Storage

Safeguard your valuable biological and medical samples with the BIOSAFE VENUS® Sample Storage system available from LAF tech, the leading supplier of lab and scientific equipment in Australia.

Contamination Control Strategy for Australian Sterile Facilities: What Annex 1 Actually Expects

A sterile cleanroom aseptic line, gowned operators, and a floating contamination strategy risk map.

For Australian sterile manufacturers, Annex 1 has raised the standard from having individual contamination controls to showing that contamination risk is understood and managed through one connected strategy. Under PE009-17, the updated Annex 1 now applies in Australia, and the contamination control strategy, or CCS, sits at the centre of that expectation.

A CCS is not a document created only for inspection. It should explain how the facility prevents contamination, how it verifies that controls are working, and how it responds when performance starts to drift. If contamination controls are scattered across SOPs, validation reports, monitoring records, training files, and deviation investigations without a clear structure linking them, the site may struggle to show that contamination is being managed coherently.

A CCS is not just monitoring with a new title

One of the easiest mistakes is to reduce the CCS to an environmental monitoring plan. Monitoring matters, but it comes after design, process control, and procedures. Sterility assurance starts with the way the facility, equipment, process, and workflows are designed. Monitoring then confirms whether those controls remain effective.

A practical CCS starts with contamination pathways. Where can microbial, particulate, or endotoxin contamination arise? How could it reach exposed product, sterile components, product contact surfaces, or critical process steps? Which controls are meant to stop that, and how is the site verifying that they work over time? If a CCS only lists sampling points and alert limits, it is incomplete.

The CCS needs to sit inside the pharmaceutical quality system

The CCS should connect to the systems that govern sterile manufacture: change control, deviations, CAPA, qualification, validation, cleaning and disinfection, monitoring, maintenance, training, material control, and periodic review.

It also has to stay current. It should be reviewed when processes change, new equipment is introduced, cleanroom layouts are revised, disinfectants are changed, transfer routes are altered, or monitoring trends indicate loss of control.

Design is a primary contamination control

Annex 1 gives strong weight to design because prevention is more reliable than detection. That includes facility layout, room segregation, HVAC design, utilities, transfer paths, equipment design, and process configuration. It also includes reducing human intervention in critical areas through isolators, RABS, automation, closed processes, and preassembled sterile assemblies.

A strong CCS should show how design reduces contamination risk before monitoring is discussed. It should explain how operator exposure has been limited, open handling reduced, first air protected, and material and equipment movement controlled.

Airflow, pressure, and transfer controls need to be specific

Sterile operations depend heavily on how air, people, materials, and equipment move through the facility. A CCS should describe those controls in concrete terms. That includes how airflow protects critical zones, how unidirectional airflow has been assessed, how pressure cascades are maintained where relevant, and what happens when warnings or alarms occur. It should also explain how materials are transferred into higher-grade areas, how items are approved and disinfected before entry, and how airlocks or pass-through arrangements support control.

Where these controls rely on monitored data, the system behind that data matters. In some facilities, that may mean using an environmental monitoring platform such as Lighthouse’s LMS Pharma and LMS Express, along with Vaisala’s viewLinc Cloud or Enterprise system to capture, review, and alarm environmental conditions in a controlled way. The point is to make sure critical controls have reliable, reviewable data behind them.

Cleaning, disinfection, and barrier integrity need evidence

Annex 1 expects cleaning and disinfection to be supported by evidence, not routine habit. A written programme is necessary, but it also needs justification and validation. The site should be able to show how cleaning removes residues and debris that may interfere with disinfectant performance, and how disinfectant selection, contact time, use conditions, and effectiveness are controlled in practice.

Barrier systems also need detail. For isolators and RABS, the CCS should define glove management, material suitability, inspection, replacement frequency, and integrity testing in a way that matches the actual system and process risk.

Personnel remain important, but they are not the only control

Personnel are a major source of risk in sterile manufacture, but contamination should not be treated as a behaviour problem alone. The expectation is to control that risk through design, procedures, qualification, and disciplined operation.

Training should therefore be specific to sterile risks. Operators need to understand airflow protection, intervention risk, gowning discipline, transfer practice, cleanroom movement, and the reasons behind site controls. A useful CCS links personnel controls to contamination pathways and shows how operator involvement has been reduced where possible.

Monitoring should drive decisions

Environmental and process monitoring remain essential, but Annex 1 expects monitoring to be risk-based and useful. Collecting data is not enough unless the data supports action. A CCS should explain why the monitoring strategy suits the process and facility, how viable and non-viable monitoring support contamination control, how alert and action responses are defined, how trends are reviewed, and how results feed into investigations, batch assessment, and improvement work.

Where continuous or targeted monitoring is needed, the tools should fit the application. A remote viable monitoring solution such as Lighthouse ActiveCount may support continuous microbial monitoring in critical spaces, while a portable particle counter such as the Lighthouse APEX Z3 may be better suited to qualification work, spot checks, or investigations. The equipment itself is not the CCS, but it can support verification when chosen and validated properly.

Monitoring data also has to be credible. That is why calibration, testing, qualification, and system validation should sit close to the CCS. LAF tech’s NATA-accredited testing, calibration, IOQ, commissioning, and validation services fit into this part of the picture because monitoring data needs to be defensible.

What Annex 1 expects in practice

A review-ready CCS should read like an operating control framework, not a high-level summary. It should show how contamination risks have been identified, what controls are in place, why they are appropriate, how they are verified, and how the system is reviewed over time.

For Australian sterile facilities, that means the CCS should be current, connected to real operations, and detailed enough to support change control, qualification, investigation, monitoring, and management review.